Active Power Filter (APF), Static Var Generator (SVG)
Employing efficient power electronic topology and advanced all-digital control technology to dynamically compensate for reactive current and harmonic current, improve power factor, and eliminate harmonic current.
Classification:
Active power quality device
Key words:
Passive power quality device
Product Description
|
Active Power Filter (APF) |
Static Var Generator (SVG) |
System Voltage (V) |
400V AC ±10% |
|
Frequency (Hz) |
50+/-5% |
|
Wiring Method |
Three-phase three-wire/Three-phase four-wire |
|
Capacity |
100A, 125A, 150A |
75kVar, 100kVar |
Function |
APF/SVG is a flexible power converter. It first measures the reactive current and harmonic current generated by the load, and then generates a new reactive current and harmonic current with the same amplitude and opposite phase, thereby eliminating most of the reactive current and harmonic current in the power grid. |
|
Difference |
APF is a harmonic compensation device used to eliminate harmonics in the system. |
SVG is a static reactive power compensation device used to improve the system power factor. |
Composition |
The APF/SVG system mainly includes the main contactor KM1, pre-charge contactor KM2, pre-charge resistor R, filter inductor L, voltage-type PWM rectifier bridge (VSR), and DC bus capacitor C, etc. |
|
Filtering Rate |
≥90% (within the ordered capacity range, and the load harmonic content is higher than 30% of the ordered capacity) |
|
Filtering Range |
2~25th harmonics |
|
Operating Mode |
Single unit or parallel operation |
|
Operation Mode |
Multiple operation modes selectable, remote or local |
|
Overload Protection |
Automatic current limiting at 100% rated output |
|
Other Protection |
Overvoltage protection, undervoltage protection, overtemperature protection |
|
Operating Ambient Temperature |
-10℃~40℃ |
|
Storage/Transportation Temperature |
-40℃~60℃ |
|
Product Features |
1. Adopts an active module vertical structure design, using large-capacity IGBT power devices. The devices are selected with an effective value of more than 3 times, leaving a large safety margin. It can work for a long time under large load impacts; 2. Harmonic compensation, reactive power compensation, and simultaneous harmonic and reactive power compensation, multi-purpose in one machine; 3. Has harmonic division compensation function and can set the reactive power compensation ratio; 4. Has various protection functions such as overcurrent, overvoltage, undervoltage, and overtemperature, ensuring safe and reliable system operation; 5. Can be flexibly combined to meet different capacity requirements. While achieving standardized production, it also improves the equipment's 6. Reliability and maintainability, greatly facilitating system installation and maintenance; 7. Single-module independent air duct design can effectively isolate the adhesion of environmental dust and improve the product heat dissipation rate; 8. Fault self-diagnosis and self-start function. The device has a self-recovery function that is not caused by the device itself. Before self-recovery, it needs to automatically diagnose the external power grid and the device itself. Self-start is possible only after the diagnosis is passed. |
Related Products
online message
If you are interested in our products, please leave your email, we will contact you as soon as possible, thank you!
Beijing YiNeng Electric Technology Co., Ltd.
Address: No.27, Keyuan Road, Daxing District, Beijing

Copyright©Beijing YiNeng Electric Technology Co., Ltd.